Object 20A7h: Latch position 2, positive or negative edge
This object is used to output the position or a time, depending on CAP1.MODE, at which the first positive or negative edge occurred on a signal, that can be configured with CAP1.TRIGGER. Latch enable must be active for that purpose (see object 20A4 and 20A5).
Index |
|
Name |
Latch position 2 positive or negative CAP1.PLFB |
Object code |
VAR |
Data type |
INTEGER32 |
Category |
optional |
Access |
ro |
PDO mapping |
possible |
Value range |
INTEGER32 |
Float scaling |
var |
Default value |
0 |
-
- "Float Scaling" is applied to objects matching floating-point parameters in WorkBench/Telnet. Float scaling "variable" (var) means scaling is not fixed but depends on other settings or parameters.
Examples for fixed scaling:
Object 607Ah is listed as 1:1 - this means that commanding a value of 1000 in SDO 607Ah is equivalent to entering MT.P 1000.000 in WorkBench.
Object 3598h is listed as 1000:1 - this means that commanding a value of 1000 in SDO 3598h is equivalent to entering IL.KP 1.000 in WorkBench.